Language: EN
Concept image showing generator sets and synchronizing control panels
GENERATOR · SYNCHRONIZING PANELS · AUTOMATION

Manage your power.
With confidence.

Generator and transformer synchronization, synchronizing panels and power automation solutions.

Brands we use

For synchronization and power control systems.

  • DEIF
  • ComAp
  • WOODWARD
01 — OUR SERVICES

Every source. One coordinated system.

We bring generator automation, panel control
and field applications together.

03

Power
automation

Automation applications for monitoring, managing and coordinating power sources.

MONITORING & CONTROL
04

Commissioning

Site checks, operating sequence tests and commissioning.

FIELD APPLICATIONS
05

Troubleshooting &
technical support

Fault diagnosis and repair support for synchronization, panels and power automation systems.

FAULT DIAGNOSIS & SUPPORT
YOUR PROJECT

Let’s define
your requirements
together.

Contact us
02 — APPLICATIONS

Our work, in the field.

Control panels and operator screens from EDR’s application archive.

Select a photograph to view it in detail.
Overview of six transformers and six generators on a Weintek HMI
01 Six-transformer and six-generator monitoring
Two transformers, two generators and bus-tie control on a Weintek HMI
02 Dual-transformer and generator control
Automation panel with Siemens PLC, circuit breakers, relays and terminals
01 PLC automation
Generator and transformer automation on a Weintek HMI
02 Generator and transformer monitoring
Transformer and generator single-line diagram on a Delta HMI
03 Transformer and bus-tie control
Siemens HMI and Woodward LS-5 synchronization controller
04 Mains transfer synchronization
Mains and four-generator synchronization system on a Weintek HMI
05 Mains and generator control
03 — OUR REFERENCES

Our references.

01

PROKOLON ELECTRICAL & ELECTRONICS ENGINEERING

Generator synchronization project

05

Meyta Enerji

INTERACTIVE DEMONSTRATION

Experience synchronization.

Adjust the generator frequency towards 50 Hz and close the simulated breaker. Explore the operating principle in this short demonstration.

This demonstration is for educational use. Actual synchronization also requires verification of voltage, phase angle and protection conditions.

Open the full synchronization simulator ↗
SINGLE-LINE VIEWMains · Generator synchronizationQF2 · OPEN
The mains transformer feeds the common busbar through closed breaker QF1. Generator breaker QF2 is initially open. MAINSGENERATOR G~ 400 V · 50.00 Hz400 V · 49.50 Hz QF1IQF2O COMMON BUSBAR · 400 VFACILITY LOAD

Target range: 49.90–50.10 Hz.

04 — EDR OTOMASYON

Generator
automation.

EDR Otomasyon (EDROtomasyon), legally EDR Otomasyon Elektrik San. ve Tic. Ltd. Şti., provides generator automation, generator and transformer synchronization, synchronizing panels and power automation.

Our commissioning and troubleshooting services also address the on-site technical needs of power systems.

SynchronizationAutomationTechnical services
05 — CONTACT

Let’s discuss
your project.

A new system, commissioning or fault support.
Tell us what you need.

+90 535 986 10 26
ADDRESS
Esenlik Mahallesi, 9042 Sokak No: 2
Open map